 testing standards
Trentec Provides environmental qualification services for equipment in both mild and harsh environmental service conditions. Qualification programs are done by analysis, test, or a combination of both. Methodology used depends on the equipment and its safety function, environmental service conditions and other factors. Trentec can also provide support for EMI/RFI testing and Software Validation and Verification.
Harsh Environmental Testing |
- Material Identification
- System 1000 Material Database,
Aging and Radiation Effects Library
- Radiation Aging
- Thermal Aging
- Humidity Testing
- LOCA / HELB Chambers
- Power:
- 120V / 1f / 60 Hz up to 500A AC
- 240V / 3f / 60 Hz up to 100A AC
- 480V / 3f / 60 Hz up to 600A AC
- 600V / 1f/ 60 Hz up to 500A AC
- 0-120V / 1f / 60 Hz up to 30A AC
- 0-480V / 3f / 60 Hz up to 30A AC
- 0-700A AC @ 12V
- 0-1400A AC @ 6V
- 0-250V up to 350A DC
- Pneumatics:
- 0-120 PSIG shop air
- 0-3300 PSIG Bottled air
- 0-2500 PSIG Bottled nitrogen
- 0-600 CFM
- Hydraulics: 0-10,000 PSIG static
- Water: 0-100 PSIG at 10 GPM shop water
- Testing Standards Utilized: IEEE 323-1974/1983
10 CFR 50.49
|
| Mild Environmental Testing |
- Mild Analysis: Material aging & radiation effects library used to evaluate the expected life of components installed in a mild environment.
- Temperature: 0 - 50°C (60°C for some components)
- Humidity: 40 - 95% RH non condensing
- Radiation: 10E3 Rads for electronics
10E4 Rads for most electromechanical devices
10E6 Rads for phenolic components
- Testing Standards Utilized: IEEE 323-1974/1983
|
| To
request additional or more specific information, please
click here to use our Request Info Form, or phone us
at (513) 528-7900 , Fax: (513) 528-9292.
|
|
 |
| Engineering, manufacturing and installation |
 |
| Equipment Qualification Services |
 |
| Seismic Qualification |
 |
| Environmental Qualification |
 |
| EPRI/SQURTS Program |
 |
| Nuclear Facility Replacement Parts and Services |
 |
| Concrete Cutting |
| |
|
 |