Home About Trentec Nuclear Products & Services Contact Us
  Environmental qualification
testing standards
Trentec Provides environmental qualification services for equipment in both mild and harsh environmental service conditions. Qualification programs are done by analysis, test, or a combination of both. Methodology used depends on the equipment and its safety function, environmental service conditions and other factors. Trentec can also provide support for EMI/RFI testing and Software Validation and Verification.

Harsh Environmental Testing
  • Material Identification
  • System 1000 Material Database, Aging and Radiation Effects Library
  • Radiation Aging
  • Thermal Aging
  • Humidity Testing
  • LOCA / HELB Chambers
  • Power:
    • 120V / 1f / 60 Hz up to 500A AC
    • 240V / 3f / 60 Hz up to 100A AC
    • 480V / 3f / 60 Hz up to 600A AC
    • 600V / 1f/ 60 Hz up to 500A AC
    • 0-120V / 1f / 60 Hz up to 30A AC
    • 0-480V / 3f / 60 Hz up to 30A AC
    • 0-700A AC @ 12V
    • 0-1400A AC @ 6V
    • 0-250V up to 350A DC
  • Pneumatics:
    • 0-120 PSIG shop air
    • 0-3300 PSIG Bottled air
    • 0-2500 PSIG Bottled nitrogen
    • 0-600 CFM
  • Hydraulics: 0-10,000 PSIG static
  • Water: 0-100 PSIG at 10 GPM shop water
  • Testing Standards Utilized: IEEE 323-1974/1983 10 CFR 50.49
Mild Environmental Testing
  • Mild Analysis: Material aging & radiation effects library used to evaluate the expected life of components installed in a mild environment.
  • Temperature: 0 - 50°C (60°C for some components)
  • Humidity: 40 - 95% RH non condensing
  • Radiation: 10E3 Rads for electronics 10E4 Rads for most electromechanical devices 10E6 Rads for phenolic components
  • Testing Standards Utilized: IEEE 323-1974/1983
To request additional or more specific information, please click here to use our Request Info Form, or phone us at (513) 528-7900 , Fax: (513) 528-9292.
 
Contact Us | Privacy Policy | Other CWFC Solutions