nuclear
containment
Trentec provides the highest levels of seismic qualification and analysis available by test and/or analysis. Software analysis includes ALGOR and ANSYS finite element analysis. All physical and software testing is based on common standards, including
- IBC/UBC Commercial Seismic Code
- IEEE344
- IEEE382
- ASME Division 1 Section III Design Code
- AISC Structural Steel Design
Code
|
|
|
|
Triaxial Table's Performance Characteristics |
- Force Rating: 30,000 force pounds vertical
20,000 force pounds horizontal
- Flow Rating: 33 IPS vertical, 25 IPS front to back, 23 IPS side
to side
- Displacement: 8 inches peak to peak - three directions
- Table Dimensions: 10' x 10'
- Max. Specimen Weight: ;10,000
LB
|
| Uniaxial Table's Performance Characteristics |
- Orientation: Horizontal, Vertical, or Dependent Biaxial
- Force Rating: 7,000 force pounds
- Displacement: 12 inches peak to peak
- Table Dimensions: 30" x 30"
- Max. Specimen Weight: 450
LB
|
| Frequency/Dampening
Characteristics |
- Frequency: Typical
1 - 100 Hz, 400 Hz max.
- Shock Dampening: 0.1%
to 10%
- Input Signal: Random
multi-frequency or complex waveforms Uniaxial Table
- Testing Standards Utilized: IEEE
344 - 1975/1987, USNRC Regulatory Guide 1.100 Rev. 1 and related
standards such as ANSI C37.98 for relays. Test Plan & Report
Standardization per EPRI-SQURTS Utility Specifications
|
| To
request additional or more specific information, please
click here to use our Request Info Form, or phone us
at (513) 528-7900 , Fax: (513) 528-9292.
|
|
 |
| Engineering, manufacturing and installation |
 |
| Equipment Qualification Services |
 |
| Seismic Qualification |
 |
| Environmental Qualification |
 |
| EPRI/SQURTS Program |
 |
| Nuclear Facility Replacement Parts and Services |
 |
| |
|
 |