Home About Trentec Nuclear Products & Services Contact Us
  Seismic qualification
nuclear containment
Trentec provides the highest levels of seismic qualification and analysis available by test and/or analysis. Software analysis includes ALGOR and ANSYS finite element analysis. All physical and software testing is based on common standards, including
  • IBC/UBC Commercial Seismic Code
  • IEEE344
  • IEEE382
  • ASME Division 1 Section III Design Code
  • AISC Structural Steel Design Code

Triaxial Table's Performance Characteristics

  • Force Rating: 30,000 force pounds vertical 20,000 force pounds horizontal
  • Flow Rating: 33 IPS vertical, 25 IPS front to back, 23 IPS side to side
  • Displacement: 8 inches peak to peak - three directions
  • Table Dimensions: 10' x 10'
  • Max. Specimen Weight: ;10,000 LB
Uniaxial Table's Performance Characteristics
  • Orientation: Horizontal, Vertical, or Dependent Biaxial
  • Force Rating: 7,000 force pounds
  • Displacement: 12 inches peak to peak
  • Table Dimensions: 30" x 30"
  • Max. Specimen Weight: 450 LB
Frequency/Dampening Characteristics
  • Frequency: Typical 1 - 100 Hz, 400 Hz max.
  • Shock Dampening: 0.1% to 10%
  • Input Signal: Random multi-frequency or complex waveforms Uniaxial Table
  • Testing Standards Utilized: IEEE 344 - 1975/1987, USNRC Regulatory Guide 1.100 Rev. 1 and related standards such as ANSI C37.98 for relays. Test Plan & Report Standardization per EPRI-SQURTS Utility Specifications
To request additional or more specific information, please click here to use our Request Info Form, or phone us at (513) 528-7900 , Fax: (513) 528-9292.
 